Application
Plug-in component designed to create a square end plate at the open end of a Beam Section TP F 100 or a Beam Bracket/Cantilever bracket AK F 100. Variation "T" with octagonal insert allows full utilisation of beam section within the space required by the End Support WBD itself.
Installation
Depending on the situation, different options are recommended:
a) Directly to building structure: 4 x suitable wall anchors and 4 Self Forming Screws FLS applied to the square/octagonal insert
b) To traditional steel beams between 80 – 310 mm flange dimensions: 1x Assembly Set 5P M12 S, M16 S and 4 Self Forming Screws FLS applied to the square/octagonal insert
c) To Sikla Simotec steel beams 100/120: with Bracket Plates FV 100/120 when positive mechanical connection required
The Beam Section TP F 100 connected to the End Support WBD F 100 has to be screwed with 4 Self Forming Screws FLS F. On each of the opposite sides 2 Self Forming Screws FLS F are necessary. The permissible distance between base plate WBD and profile must not exceed 30 mm.
Technical Data
| Type | Base plate finish |
for flange width [mm] |
Dimensions of base plate |
Slots in base plate [l x b) |
|---|---|---|---|---|
| WBD F 100-80/120 | flat | 80 - 120 | 220 x 220 x 12 | 30 x 14 |
| WBD-P F 100-121/160 | corrugated | 121 - 160 | 320 x 260 x 12 | 20 x 14 |
| WBD-P F 100-161/200 | corrugated | 161 - 200 | 320 x 310 x 12 | 20 x 18 |
| WBD-P F 100-201/310 | corrugated | 201 - 310 | 420 x 220 x 12 | 55 x 18 |
| WBD F 100-T | flat | 80 - 120 | 220 x 220 x 12 | 30 x 14 |
| Type | e [mm] |
L [mm] |
t1 [mm] |
Slots in base plate for |
|---|---|---|---|---|
| WBD F 100-80/120 | max. mögl. Abstand | 232 | - | M12 |
| WBD-P F 100-121/160 | max. mögl. Abstand | 232 | 27 | M12 |
| WBD-P F 100-161/200 | max. mögl. Abstand | 232 | 27 | M16 |
| WBD-P F 100-201/310 | max. mögl. Abstand | 232 | 27 | M16 |
| WBD F 100-T | max. mögl. Abstand | 192 | - | M12 |
| configuration: | Plate welded to square F 100 resp. octagonal element F 100 (only WBD F 100-T) |
| material: | Steel, HCP |
Approvals
CE mark, according to EN 1090.

| Code | Name | Weight | Number of pieces | ||
|---|---|---|---|---|---|
| 113079 | F 100-T 80/120 | 5.28 | 1 | Information request | |
| 113075 | F 100 80/120 | 6.20 | 1 | Information request | |
| 117167 | WBD-P F 100-121/160 | 9.72 | 1 | Information request | |
| 117168 | WBD-P F 100-161/200 | 11.20 | 1 | Information request | |
| 117169 | WBD-P F 100-201/310 | 10.29 | 1 | Information request |